BG1100M Direct Spark Ignition Control
Application
The BG1100M is a microprocessor based ignition
control. The microprocessor provides reliable software
control of all timings and operates a diagnostic red
Light-Emitting Diode (LED). It is designed for direct
burner supervision and can be used with all gases. It
provides ignition sequence, flame monitoring, and
safety shutoff for direct spark ignition boilers, furnaces
and other heating appliances. For a complete listing of
specifications, refer to the Technical Specifications
section.
Installation
IMPORTANT: Only qualified personnel should
install or service BASO Gas Products®. These
instructions are a guide for such personnel. Carefully
follow all instructions for the appliance.
IMPORTANT: Make all gas installations in
accordance with applicable local, national, and
regional regulations.
!
WARNING: Risk of Explosion or Fire.
Do not install the control in an area that is exposed
to water (for example, dripping, spraying, rain). Do
not use the control if it has been exposed to water.
Exposure to water may cause malfunction and can
lead to an explosion or fire and may result in severe
personal injury or death.
IMPORTANT: This control is approved for use
with only noise suppression (resistive) spark wires. If
the application has copper wire, it must be replaced.
Instructions for installing the burner/igniter-sensor are
typically provided by the appliance manufacturer. It is
important to follow those instructions. If such
information is not included, refer to the Mounting
section.
Mounting
!
CAUTION: Risk of Electric Shock.
Disconnect power supply before making electrical
connections to avoid electric shock.
!
WARNING: Risk of Explosion or Fire.
Shut off the gas supply at the main manual shutoff
valve before installing or servicing the control.
Failure to shut off the gas supply can result in the
release of gas during installation or servicing, which
can lead to an explosion or fire, and may result in
severe personal injury or death.
IMPORTANT: Do not mount the control where
it can be exposed to direct infrared radiation from the
main burner or to temperatures in excess of the
maximum product temperature rating.
Page view 0
1 2 3 4 5 6 ... 14 15

Summary of Contents

Page 1 - Installation

Installation Instructions Issue Date June 26, 2014 © 2014 BASO Gas Products. 1 Part No. BASO-INS-BG1100M, Rev. E www.baso.com BG11

Page 2

10 BG1100M Direct Spark Ignition Control Installation Instructions Maintenance Requirements in Severe Environments Regular preventive maintenance i

Page 3 - Chassis or Frame

BG1100M Direct Spark Ignition Control Installation Instructions 11 Table 3: Ignition Control Accessories Part Number Description RAA1600A-601D Ra

Page 4 - Operation

12 BG1100M Direct Spark Ignition Control Installation Instructions Notes

Page 5 - Troubleshooting

BG1100M Direct Spark Ignition Control Installation Instructions 13 Notes

Page 6

14 BG1100M Direct Spark Ignition Control Installation Instructions Notes

Page 7

BG1100M Direct Spark Ignition Control Installation Instructions 15 Technical Specification Product BG1100M Direct Spark Ignition Control Ignition T

Page 8

2 BG1100M Direct Spark Ignition Control Installation Instructions Location Considerations Choose a location that provides the shortest, direct cabl

Page 9

BG1100M Direct Spark Ignition Control Installation Instructions 3 VALVE(COM)VALVEGNDBURNERGND24VSENSESPARKChassis or FrameGroundThermostatHighTem p

Page 10 - Repairs and Replacement

4 BG1100M Direct Spark Ignition Control Installation Instructions Setup and Adjustments Checkout ! WARNING: Risk of Explosion or Fire. Verify that

Page 11

BG1100M Direct Spark Ignition Control Installation Instructions 5 Troubleshooting If the system does not function properly, determine the cause usi

Page 12

6 BG1100M Direct Spark Ignition Control Installation Instructions Table 2: Red LED Error Indications Flash Code Flash Code Description Troubleshoot

Page 13

BG1100M Direct Spark Ignition Control Installation Instructions 7 NoYesIdle StateCall for heatfrom the thermostatPOWER TO CONTROLOne second fordiag

Page 14

8 BG1100M Direct Spark Ignition Control Installation Instructions YesNoNoYesTurn on powerand gas.Close thermostatcontacts.Module red LEDdid not lig

Page 15 - Technical Specification

BG1100M Direct Spark Ignition Control Installation Instructions 9 Continuedfrom previous pagePilot is litNoYesYesNoAfter burner islit, do valves tu

Comments to this Manuals

No comments